Bosch EasyControl Adapter
Description
Bosch EasyControl Adapter
- modulating heating systems with OpenTherm-protocol
- on/off-appliances and district heating systems
- older boilers with iRT-protocol
Check the appliance’s installation instructions to check which communication protocol your boiler uses.
The adapter switches between the heating system and the EasyControl CT200 thermostat. For best results, install the adapter right next to the heating system. Then simply plug in the power plug - ready!
Note: When connected to equipment with an On-Off connection, the EasyControl CT200 thermostat provides access only to the main functions, namely the remote control and programming of the heating equipment via the Internet, as well as the presence detection function.
EasyControl adapter instructions
Power supply = 20 Vdc. Rated current consumption <2.5 W. Dimensions (width x height x depth) = 134 x 115 x 37 mm. Weight = 230 gr. Permissible ambient temperature 0-50 ° C; Permissible storage temperature 0-60 ° C. Permissible relative humidity 10-90%. IP20 protection mode.
Rated current (minimum) @ 18 V: 10 mA. Contact load (maximum) @ 250 VAC = 5 A. Cable cross section (maximum) = 2.5 mm². EasyControl adapter cable length (maximum) - thermal generator = 3 m. EasyControl adapter cable length (maximum) - thermostat = 100 m.