Air purifier MC55W
Description
Air purifier Daikin MC55W with Streamer technology
Product Features
- Effectiveness against respiratory viruses evaluated by Institute Pasteur de Lille
- Pure air thanks to Daikin ‘Catch and Clean’ approach in decomposing harmful substances
- High performance electrostatic HEPA filter which doesn’t clog easily, hence causes low pressure loss
- One of the most silent Air Purifier range on the European market
- No need to change the filter for ten years, resulting in low maintenance costs
- Purifies the air in rooms up to 82m², perfect for large living areas.
Flash Streamer
Using electrons to trigger chemical reactions with air borne particles, the Flash Streamer breaks down allergens such as pollen and fungal allergens and removes bothersome odours providing a better, cleaner air.
Specifications
Type Air Purifier
Application Floor standing type
Casing Colour White
Dimensions Unit Height 500 mm, Width 270 mm, Depth 270 mm
Weight Unit 6.8 kg
Applicable room area m² 41 (1), 82 (2)
CADR m³/h 320
Air purifying operation Power input Turbo kW 0.037
M kW 0.015
L kW 0.010
Silent kW 0.008
Sound pressure level Air purifying operation Turbo dBA 53
Medium dBA 39
Low dBA 29
Silent dBA 19
Fan Air flow rate Air purifying operation Turbo m³/h 330
Medium m³/h 192
Low m³/h 120
Silent m³/h 66
Dust collecting method Electrostatic HEPA filter
Deodorizing method Flash streamer + Deodorizing catalyst
Safety devices Item 01 Safety switch (Operation stops when the Streamer unit cover is open)
Standard Accessories Remote controller 1
Remote control holder 1
Electrostatic HEPA filter 1
Deodorising filter 1
Operation manual 1
Power cord m 1.8
Power supply Phase 1~
Frequency Hz 50/60
Voltage V 220-240/220-230
Running current Air purifying operation Turbo A 0.32
Medium A 0.14
Low A 0.10
Silent A 0.08
Notes (1) - The applicable room area is appropriate for operating the unit of maximum fan speed (HH). Applicable room area indicates the space where a certain amount of dust particles can be remover in 30 minutes. (JEM 1467)
(2) - Converted to NRCC standards from test values in accordance with JEM1467.
(3) - Converted to CADR standards from test values in accordance with JEM1467.
(4) - Operating sound levels are the average of values measured at 1m away from the front, left, right and top of the unit. (These are equal to the values in an anechoic chamber)
(5) - Electrostatic HEPA filter is attached in the unit.
(6) - Other function: Active plasma ion function. Auto-restart function.