Air/Water Heat Pump Vitocal 100-S AWB-M 101.B08
Description
Air/Water Heat Pump split type Viessmann Vitocal 100-S AWB-M 101.B08 230 V, R32
Heat pump with electric drive split model, with indoor and outdoor unit. For heating and preparation of domestic hot water in heating installations.
Indoor unit with Vitotronic 200 heat pump automation, high-efficiency recirculation pump for the secondary circuit, 3-way switching valve, diaphragm expansion vessel and integrated safety group.
Low operating costs due to high COP value (COP = coefficient of performance) according to EN 14511: up to 5.1 (A7/W35) and up to 3.8 (A2/W35)
Power regulator and DC inverter for high efficiency in partial load operation
Indoor unit with high efficiency pump, heat exchanger, 3-way diverter valve, safety elements, diaphragm expansion vessel and automation, with integrated instantaneous coolant heater for -E and -AC variants.
User-friendly Vitotronic automation with text display and graphic display.
Comfortable thanks to the reversible construction, which allows heating and cooling at different temperature levels (AC variant).
Optimized use of electricity self-generated by photovoltaic installations
Cascade function for up to 5 heat pumps.
Possibility to connect to the Internet via Vitoconnect (accessory) for use and service via Viessmann apps.
Connectivity via WLAN: With the ViCare application, the automation controlled by the outside temperature can be accessed via the Internet. Vitoconnect accessories are required.
Automation Vitotronic 200 Type WO1C, for operation controlled by the external temperature:
Digital heat pump automation
Adjusting the temperature in the domestic hot water storage tank
Use through menus
Use of an additional gas/liquid fuel boiler
Cascade connection for up to 5 Vitocals (accessories required)
Use of Viessmann Vitovent compatible ventilation units
Swimming pools heating
Optimizing the use of own electricity
Integrated counter for the amount of heat
The order of an instant heating agent preparer
Extensions are required for mixing valve heating circuits, to optimize self-energy use, in the case of additional oil/gas boiler and to heat swimming pools
Delivery package:
Complete heat pump, split model, composed of indoor and outdoor unit.
Indoor unit:
Built-in switching valve heating/domestic hot water preparation
Built-in high-efficiency circulation pump for the secondary circuit
Built-in safety valve and pressure gauge
Vitotronic 200 heat pump automation, controlled by outside temperature, with outside temperature sensor
Expansion tank (10 liters)
Flow switch
Wall mount
Outdoor unit
With refrigerant (R32/R410A), for pipelines with a maximum length of 10 m, with angled connections, inverter-controlled compressor and sound insulation, 4-way valve, electronic rolling valve, vaporizer, condensate pan heater and fan.
Indication! It is necessary to order BUS communication cables between the outdoor and indoor units
Technical information
Power parameters, heating according to EN14511 (A2/W35) Nominal power 6.00 kW. Absorbed electrical power 1.67 kW. Power index ε (COP) in heating mode 3.42. Power adjustment 3.6-9 kW.
Heating power parameters cf. EN14511 (A7/W35, temperature difference between flow and return 5 K) Nominal power 8.13 kW. Absorbed electrical power 1.74 kW. Power index ε (COP) in heating regime 4.66. Power adjustment 4.7-12 kW.
Heating power parameters according to EN14511 (A–7/W35) Nominal power 6 kW. Electrical power absorbed 2.22. Power index ε (COP) in heating mode 2.70. Power adjustment 2.7-7.5 kW.
Air inlet temperature Heating regime Min. -20°C / Max. 35°C
Energy efficiency class according to EU regulation no. 813/2013 Heating normal climate conditions ■Low temperature heating (W35) A+++ ■Medium temperature heating (W55) A++
Heating power data according to EU Regulation no. 813/2013 (usual climate conditions) Low temperature heating (W35) Energy efficiency ηS 176%. Nominal power P 6.4 kW. Seasonal Power Index (SCOP) 4.47. Medium temperature heating (W55) Energy efficiency ηS 129%. Nominal power P 6.67 kW. Seasonal power index (SCOP) 3.3. Sound power level according to ErP, external unit 63.6 dB(A)
Thermal agent (secondary circuit) Minimum volume flow 700 l/h. Minimum volume of heating installation, non-blocking 52 liters. loss max. of external pressure (RFH) at volumetric flow min. 700 mbar, 70 kPa7. Maximum tour temperature 58°C.
External unit dimensions Length 360 mm, Width 980 mm, Height 790 mm. Mass = 80 kg.
Internal unit dimensions Length 370 mm, Width 450 mm, Height 880 mm. Mass = 42 kg
Liquid pipe dimensions Ø6 mm
Hot gas pipe dimensions Ø12 mm
Refrigerant: R32
External unit electrical parameters: Nominal compressor voltage 1/N/PE 230 V/50 Hz. Maximum compressor working voltage 18.8 A. Cos φ 1.00. Compressor start current 4 A. Compressor fuse 1 x B32. Protection type IPX4.
Internal unit electrical parameters Heat pump automation/electronic system ■Nominal voltage heat pump automation/electronic system (internal) 1/N/PE 230 V/50 Hz ■Heat pump automation/electronic system fuse (internal) T 6.3 A/250 V ■Mains connection fuse, indoor unit 1 x B16A.