Gas condensing Boiler. Semia Condens 25A
Description
Saunier Duval Semia Condens 25A wall-mounted gas condensing Boiler.
The SemiaCONDENS thermal power plant is part of the group of condensing power plants, more efficient and quieter power plants, but also reliable and easy to use.
This condensing boiler model falls into class 5 NOx, the most efficient according to the EU standard in terms of noxious emissions. Operating noise is reduced by incorporating a superior housing insulation. The built-in pump has 2 speeds that can be changed automatically depending on the pressure losses in the heating system, thus avoiding the production of noise.
The increased modulation range (thermal power 5 kW → 25 kW on a.c.m and 5 kW → 18 kW on heating) and high efficiency, as well as the price / quality ratio make this boiler made in France reliable and accessible to everyone.
Constant ambient temperature regardless of the weather;
Ample modulation level;
Aluminum-Silicon alloy heat exchanger, patented Saunier Duval
Class 5 NOx;
Display lights
Efficiency up to 107.6 in the 30% partial load regime (40/30)
4 * heating efficiency
High efficiency pump in 2 stages;
E-BUS connection
SemiaCONDENS is equipped with an electronic e-BUS port that allows the connection of a thermostat modulator, in order to benefit from all the advantages and maximum performances that Semia CONDENS can offer.
Heating
Seasonal energy efficiency class A
Maximum heating flow temperature °C 75
Max. of the lifting temperature control °C 10-80
Maximum allowable pressure (PMS) bar 3
Nominal water flow (ΔT = 20K) l / h 779
ΔP nominal flow heating (ΔT = 20 K) bar 0.440
Approximate value of condensation volume at 50°C / 30°C l / h 1.84
G20 power / charge
Maximum thermal efficiency (factory setting-d.00) kw 15
Useful power range (P) at 50/30°C kw 5.3 -19.1
Useful power range (P) at 80/60°C kw 5-18.1
Thermal power range - hot water (P) kw 5-25.2
Maximum thermal load - heating (Q max.) kw 18.4
Minimum thermal load - heating (Q min.) kw 5.1
Maximum thermal load - hot water (Q max.) kw 25.7
Minimum thermal load - hot water (Q min.) kw 5.1
Hot water
Energy efficiency class A
Specific flow rate (D) (ΔT = 30 K) according to EN13203 l / min 12.1
Specific flow rate (ΔT = 35 K) l / min 10.4
Minimum allowable pressure bar 0.3
Maximum allowable pressure bar 10
Temperature range °C 35-60
Gas tube diameter 1/2
The diameter of the heating pipe 3/4
Gas supply pressure mbar 20
Efficient at 80/60°C 98.20%; Efficient at 50/30°C 104%
Partial load efficiency (30%) at 40/30°C 108.50%
Class Nox 5
Dimensions (Lx W x H) mm 740 x 418 x 300
Net weight kg 31.6
Supply voltage V / Hz 230V / 50Hz
Maximum power absorbed W 105
Degree of protection IPX4D