Condensing gas Boiler GB022-24 K H

Buderus
RON 4,235.00 (VAT Included) RON 4,887.19
RON 3,500.00 (VAT excluded)
Delivery costs are not included
Buderus
SKU 7736902967
Limited stock

Description

Condensing gas Boiler Buderus Logamax plus GB022-24 K H flue kit included

The wall-mounted gas condensing boiler, Logamax plus GB022 adapts to perfectly meet your heating and domestic hot water needs. It is particularly robust, thus reliably ensuring constant comfort.

The compact dimensions of the boiler allow a simple and flexible installation, being ready for use in a very short time. It is equipped with an advanced LCD screen for simple and quick control.

The Logamax plus GB022 boiler is particularly adaptable. With a high modulation ratio of 1:5, it effectively adapts to domestic hot water requirements, being very efficient from the point of view of consumption.

The equipment is characterized by a high power for the preparation of domestic hot water of up to 25 kW. Thus, there is always a sufficient amount of hot water available. In addition, the boiler has an extremely efficient operation
silent. In other words, you can shower at any time of the day or night without disturbing anyone.

With a compact and modern design, but at the same time robust, the Logamax plus GB022 boiler integrates perfectly into any living space, offering elegance to the place where it is placed. The hydraulic connections are not visible
under the equipment at the front and, with a depth of only 300 mm and a height of 710 mm, it can be perfectly integrated into the smallest rooms, such as the hallway.

Integration into an existing heating system is possible thanks to the modular design and the use of a control technology with proven efficiency.

Installation and maintenance operations can be carried out simply thanks to the compact design. The thermal unit weighs less than 36 kg and allows frontal access to the internal components. This saves time and reduces maintenance costs.

Advantages of GB022:

  • increased efficiency thanks to a high modulation ratio of 1:5
  • high power in DHW brewing mode
  • compact design
  • simple installation
  • various installation possibilities thanks to the horizontal installation option (hydraulic connection)
  • compatible with innovative systems thanks to the EMS interface
  • elegant and functional design with an advanced LCD screen.

The delivery set includes:

Logamax plus heating unit GB022-24 K H (7736901496)
Exhaust gas horizontal kit L=1000 mm (7738112495).

Specifications

Nominal heat output max. (Pmax) 40/30°C 25.2 kW
Nominal heat output max. (Pmax) 50/30°C 25.2 kW
Nominal heat output max. (Pmax) 80/60°C 24.0 kW
Nominal thermal load max. (Qmax) 24.5 kW
Nominal thermal power min. (Pmin) 40/30°C 5.3 kW
Nominal thermal power min. (Pmin) 50/30°C 5.3 kW
Nominal thermal power min. (Pmin) 80/60°C 4.8 kW
Nominal thermal load min. (Qmin) 4.9 kW
Nominal heat output max. hot water (PnW) 25.0 kW
Nominal thermal load max. for hot water (QnW) 25.5 kW
Max. power output heating curve 40/30°C 103%
Max. power output heating curve 50/30°C 102%
Max. power output heating curve 80/60°C 98%
Power output min. heating curve 36/30°C 109.5%
Power output min. heating curve 40/30°C108%
Power output min. heating curve 50/30°C 108%
Power output min. heating curve 80/60°C 97.5%
Normalized degree of use at the heating curve 75/60°C105%
Normalized degree of use at heating curve at 30% load 40/30°C 108.5%
Gas connection value
Methane gas H (Hi(15 °C) = 9.5 kWh/m3) m3/h 2.62 m3/h
Propane (Hi = 12.9 kWh/kg) 1.89 kg/h
Butane (Hi = 12.7 kWh/kg) 2.24 kg/h
Admissible gas connection pressure
Methane gas H 17 - 25 mbar
Liquefied gases mbar 25 - 35 mbar
Expansion vessel
Pressurization 0.75 bar
Nominal volume of the expansion tank according to EN 13831 6 liters
Hot water
Max. quantity of hot water (with flow limiter) 10 l/min
Water temperature 35-60°C
temperature max. hot water inlet 60°C
Max. water pressure admissible 10 bar
Flow pressure min. 0.3 bar
Specific flow according to EN 13203-1 (dT = 30 K) 12.2 l/min.
Values for calculating the cross-section according to EN 13384
The mass flow rate of the burnt gases at the nominal thermal power max./min 11.31/2.40 g/s
Flue gas temperature 80/60°C at nominal heat output max./min. 70/58°C
Flue gas temperature 40/30°C at nominal heat output max./min. 50/35°C
Debris discharge pressure 125 Pa
CO2 at max. nominal heat output. 9.6%
CO2 at nominal thermal power min. 8.6%
NOx class 6
Condensed
Amount of condensate max. (TR = 30°C) 1.7 l/h
The pH value approx. 4.8

Losses when the burner is off at dT = 30 K 0.36%
Authorization data
Equipment category – II2 H 3 B/P
Installation Type – B23, B23P, B33, C13(x), C33(x), C43(x), C53(x), C63(x), C83(x), C93(x)
Overview
Electrical voltage AC ... 230 V, Frequency 50 Hz
Power absorbed max. (heating mode) 90 W
EMV limit value class –B
Sound pressure level 45 dB(A)
IP protection mode X4D
temperature max. tour 82°C
max. working pressure admissible (PMS) heating 3 bar
Allowed ambient temperature 0-50°C
Amount of hot water 7 liters
Weight (without packaging) 35 kg. Dimensions 400 × 710 × 300 mm

Details

SKU
7736902967
Categories
Weight
36 kg
Brand
Physical Characteristics
Colour
Black, White
Power
Thermal Power
19-24 kW
Boiler Type
Instant Hot Water, condensing