5%
Boiler Mynute X 35C p
This product is no longer part of the store's offer.
RON 5,043.21
(VAT Included)
RON 5,317.95
RON 4,167.94
(VAT excluded)
Delivery costs are not included
How can we help you?
Description
Gas condensing Beretta Boiler Mynute X 35C p
- New condensing heat-exchanger in stainless steel with frontal access.
- Active Combustion Control via ACC System.
- High modulation (up to 1:8).
- Low NOx: Class 6 According to European Directive UNI EN 15502.
- Low energy modulating circulator (EEI ≤ 0.20) electronically adjustable with four management modes.
- Built-in non retun valve on flues allowing Mynute X (*) certification as C(10) appliance(**) for sharing chimneys under pressure.
- HYBRID READY boiler, that can be integrated in Beretta multi energy systems via REC 10H, available as an accessory.
- Flexibility of installation: indoor, outdoor (in partially protected places) and in-wall application.
- Click-fit flue connection: fast and safety.
- Hydraulic connections and outdoor probe available as optional.
- Frost protection as standard.
- IPX5D electrical protection.
- LPG operation selectable through display parameter. LPG transformation kit not necessary. Thanks to the ACC system, the gas commutation is via electronic setting
- Can be matched with BeSMART Control working as wifi thermostat in OTBus communication, allowing extensive top
- advantages.
- (*) All models except for 40C and 40R.
- (**) A C(10) appliance means that it is designed to become connected to a common duct system, that is designed to operate under the conditions where the static pressure in the common flue duct might exceed the static pressure in the common air duct.
Useful thermal heating power = 9.7-29.2 kW; Maximum rated thermal output = 30 kW
Hot water flow (at dT 25 K) = 20.8 liters / min .; thermal power Hot water = 34.6 kW; minimum hot water flow = 2 liters / min.
Maximum permissible flow temperature = 90oC; set maximum temperature = 80oC Permissible operating overpressure = 3 bar.
Daily gas consumption = 23,046 kWh. Annual gas consumption = 17 GJ.
Electrical protection: IP X5D. Maximum electricity consumption = 28 W. Annual electricity consumption AEC = 30 kWh
Yield η1: up to 97.5%
Flue gas connection (double, coaxial) = 60/100 mm
Dimensions: HxBxA = 740 x 420 x 275 mm; Weight = 37 kg
Flow / return connections = 3/4 "; Hot / cold water connection = 1/2"; Gas connection = 3/4 ".
Details
SKU
20163566
Categories
Weight
37 kg
Brand
Physical Characteristics
Colour
White
Power
Thermal Power
29-32 kW
Boiler Type
Instant Hot Water, condensing